Search   Start
 
M2000 Multiple Beam Safety Device
 
 
A more economical solution
The M2000 muliple beam safety device offers you a comprehensive selection of resolution, range and housing options.

Dimensions and high product performance provide ideal suitability to your application. The M2000 makes a valuable contribution to increasing the cost-effectiveness of your plant.

You only have to invest in what you really need.

Features

  • Cascadable - up to 3 systems/max. 3 m cable length between the sensors/each sensor individually alignable
  • Muting with override (optional)
  • Integrated functions: with/without restart interlock (RES), external device monitoring (EDM), self-testing
  • Functions individually selectable
  • 2 protected PNP outputs
  • Beam coding to avoid mutual interference (3 addresses adjustable)

Accessories
  • Safety evaluation unit LE 20
  • Interface components "UE (universal equipment)
  • Alignment aid AR 60
  • Diagnosis via 7-segment display
  • Unit- and mirror columns
  • Heated unit columns
  • SMS (safety muting system) system solution incl. stable mounting profiles
  • Connecting cables (UL-certified)
  • Connecting plug
  • Various mounting kits
  • IP 67 protective housing
 
Technical specification
  Range for all resolutions   0.....6 m (M 2000 A/P)
0...25 m
0...70 m (2-, 3- and 4-beam systems)
 
  Resolution / number of beams   116 / 170 mm resolution
2-, 3- and 4-beam systems
M 2000 A/P, 2-beam system
 
  Response time   8 ms M 2000
7 ms M 2000 A/P
 
  Ambient operating temperature   0...+55 °C  
  Enclosure rating   IP 65  
  Safety category acc.
IEC 61 496
  type 2